FISCHER 547022 - Solar system for flat roofs with 10° inclination and Sud panel orientation SW-II BF 10° 

Visit the FISCHER Store
System Solar-Wind South II Flat roof system with tilt 10 ° -15 ° and oriented panels in the South Benefits: * No hole in the roof: the Solar-Wind South II system is locked with small modular...
Read more
Starting From
$ 19.90
Save 30%
$ 28.42
VAT Excluded ?

Get 7% off €150+, 10% off €500+ and 12% off €1000+ with promo code MW2023

Get 7% off €150+, 10% off €500+ and 12% off €1000+ with promo code MW2023

Worldwide Shipment
Worldwide Shipment We work with the best international couriers to reach our customers all over the world and deliver goods of any size or weight.
Find out more here.
Official Warranty
Official Warranty Mister Worker offers a 2-year warranty on all goods. The gurantee offered to companies/traders is valid for 1 year, free of charge.
For more information click here.
EAN
Availability
Pieces per pack
number of packs
Total pieces

547022 EAN: 8001132094839

8001132094839
Checking availability...
1
1
1
Not available
System Solar-Wind South II
Flat roof system with tilt 10 ° -15 ° and oriented panels in the South

Benefits:
* No hole in the roof: the Solar-Wind South II system is locked with small modular ballast concrete.
* Fast: the installation time for the Solar-Wind South II system is 30 minutes per kWp per pair of operators.
* Lightweight: the reduced inclination of the panels (10 ° and 15 °) and the presence of the crankcase reduce the effect of the action of the wind on the system, and then the number of weights in coverage.
* Complete: The system is suitable for a wide range of panels (width 950 ÷ 1050 mm x height 1559 ÷ 1690 mm).
* Versatile: the system is modular, allowing an extremely flexible panels layout.
* Electrically Safe: special center and end terminals allow the grounding of the system.
* Tested: tested in the wind tunnel up to 240 km / h.

Versions:
* Aluminum brackets AW 6060 T66 / T5 according to EN 755-2: 2013
* A2-70 stainless steel bolts to EN ISO 3506-1 / 2: 2009

Suitable for:
* Flat roof without drilling

Possible configurations:
* Single module horizontally

Function:
* Define the installation layout taking into account the distances to cover edges and obstacles.
* Define the number of weights (to be purchased separately) to use for each individual element (brackets or port ballast) as a function of the snow and wind loads of the installation area of ​​the plant, according to the national regulations.
* Place the front brackets SW-II BF and the brackets SW-II S-B (intermediate and final) on the cover, according to the project.
* Place the solar panels on the brackets and secure them using the terminals SW and SW-MC-II-II-MF.
* Fix the crankcase SW-II S CARTER on intermediate brackets SW-II BM-S and SW-II-S BE end to reduce the effect of the action of the wind.
* Place the ballast as designed.
* Protecting cover interposing the protective bearings SW-II PAD under the ballast.

 

  • Suitable for: Solar-Wind II South 10 °
  • Thickness [mm]: 6
  • thread: M 8
  • Weight [g]: 820