Intermediate plate in hot-dip galvanized steel SVI The intermediate plate for vertical flexible anchor systems on a wall or sloping roof Support materials: * Floors and Concrete slabs *...
  • FISCHER Intermediate plate hot-dip galvanized for wall or inclined lines SVI - 1
  • FISCHER Intermediate plate hot-dip galvanized for wall or inclined lines SVI - 3
  • FISCHER Intermediate plate hot-dip galvanized for wall or inclined lines SVI - 4
Kode
Stück pro Paket
Anzahl der Packungen
insgesamt Stücke
Verfügbarkeit
Preis (Vat Incl.) ?
Menge
535688
1
1
1
Checking availability...
€ 152,75
€ 107,68
Kode 535688
Werkstoff Galvanized
Gewicht 2,1
Height H [mm] 80
Tested type C
Stück pro Paket 1
Anzahl der Packungen 1
insgesamt Stücke 1
Verfügbarkeit Checking availability...
Preis
€ 107,68
Menge
Intermediate plate in hot-dip galvanized steel SVI
The intermediate plate for vertical flexible anchor systems on a wall or sloping roof

Support materials:
* Floors and Concrete slabs
* Concrete walls and masonry
* Elements in wood

Advantages:
* The plate SVI has passed the accelerated corrosion salt spray test according to EN ISO 9227: 2012.
* SVI The plate is tested for the simultaneous use of 4 operators (type C) according to UNI 11578: 2015 (permanent devices) and according to UNI EN 795: 2012 + CEN / TS 16415: 2013 (removable devices).
* The vertical flexible anchoring system is tested on different types of support.
* The maximum force acting on the plate is always 8 KN.
* The dimensions of the plate minimize the aesthetic impact of the safety of the coverage.

Suitable for:
* Vertical flexible anchor system (type C)

Where:
* Rope
* Sink
* Terminal clamp
* Turnbuckle
* Tension (optional)

Function:
* Make sure that the cover possesses adequate load-bearing capacity.
* Fix the plate to the support according to the instructions given in the draft safety of the coverage.
* Fill out the identification plate with the system installation date and batch number and affix the label to access the flexible horizontal anchoring system.
* The length of the span between two plates must be comprised between 5 and 15 m.
* Use the horizontal flexible anchor system (type C) with personal protective equipment (PPE) with a maximum force transmitted to the operator in case of arrest equal to 6 kN (600 kg).
* For the tensioning of lines on more spans (≥ 45 m) or with one or more deviations, it is necessary to use a portable winch with automatic grippers for steel cables.

 

  • Gewicht: 2,1
  • Height H [mm]: 80
  • Tested type: C
  • Werkstoff: Galvanized
Intermediate plate in hot-dip galvanized steel SVI
The intermediate plate for vertical flexible anchor systems on a wall or sloping roof

Support materials:
* Floors and Concrete slabs
* Concrete walls and masonry
* Elements in wood

Advantages:
* The plate SVI has passed the accelerated corrosion salt spray test according to EN ISO 9227: 2012.
* SVI The plate is tested for the simultaneous use of 4 operators (type C) according to UNI 11578: 2015 (permanent devices) and according to UNI EN 795: 2012 + CEN / TS 16415: 2013 (removable devices).
* The vertical flexible anchoring system is tested on different types of support.
* The maximum force acting on the plate is always 8 KN.
* The dimensions of the plate minimize the aesthetic impact of the safety of the coverage.

Suitable for:
* Vertical flexible anchor system (type C)

Where:
* Rope
* Sink
* Terminal clamp
* Turnbuckle
* Tension (optional)

Function:
* Make sure that the cover possesses adequate load-bearing capacity.
* Fix the plate to the support according to the instructions given in the draft safety of the coverage.
* Fill out the identification plate with the system installation date and batch number and affix the label to access the flexible horizontal anchoring system.
* The length of the span between two plates must be comprised between 5 and 15 m.
* Use the horizontal flexible anchor system (type C) with personal protective equipment (PPE) with a maximum force transmitted to the operator in case of arrest equal to 6 kN (600 kg).
* For the tensioning of lines on more spans (≥ 45 m) or with one or more deviations, it is necessary to use a portable winch with automatic grippers for steel cables.